Electropolymerization of Pyrrole-2-Carboxylic Acid and 4,4′-Dihydroxybenzophenone on Platinum Electrodes. Applications to Assemble Novel Glucose Sensors
Electroanalysis, ISSN: 1040-0397, Vol: 9, Issue: 14, Page: 1107-1112
1997
- 18Citations
- 14Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The electropolymerization of pyrrole-2-carboxylic acid (PY-2-COOH) and of 4,4′-dihydroxybenzophenone (DHB) has been carried out on Pt electrodes by scanning the potential from +0.4 V to +1.4 V (vs. SCE) for PY-2-COOH and from 0.0 V to +0.8 V (vs. SCE) for DHB, at scan rate of 2-5 mV/s, in phosphate buffer (PBS) pH 8. To test the permselectivity of these polymers, cyclic voltammograms of HO ascorbic acid (AA), uric acid (UA) and acetaminophen (APAP) were carried out and results were compared with those obtained at the bare electrode. The electropolymerization in the presence of glucose oxidase was also carried out. The probes were then tested as glucose sensors. Glucose was detected, by amperometric measurements at +0.6 V (vs. SCE). The linear response to glucose was in the range 7 × 10-1.8 × 10 mol/L, for the sensor prepared with PPY-2-COOH and 4 × 10-2 × 10 mol/L, for the sensor prepared with PDHB. The detection limit was 5 × 10 mol/L for PPY-2-COOH and 2 × 10 mol/L for PDHB. The response time of both polymers was 3-5 s. The stability of the electropolymerized films and the glucose probes was evaluated, in storage and operational conditions The glucose probes, stored in buffer at 4°C when not in use, showed a residual enzyme activity of 50%, after about two months.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0000180599&origin=inward; http://dx.doi.org/10.1002/elan.1140091414; https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.1140091414; http://doi.wiley.com/10.1002/elan.1140091414; https://onlinelibrary.wiley.com/doi/abs/10.1002/elan.1140091414
Wiley
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know