Electrothermal bipolar vessel sealing system vs. harmonic scalpel in colorectal laparoscopic surgery: A prospective, randomized study
Diseases of the Colon and Rectum, ISSN: 0012-3706, Vol: 52, Issue: 4, Page: 657-661
2009
- 45Citations
- 26Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations45
- Citation Indexes43
- 43
- CrossRef33
- Clinical Citations1
- PubMed Guidelines1
- Policy Citations1
- 1
- Captures26
- Readers26
- 26
Article Description
PURPOSE: This study was designed to compare the efficacy and safety of laparoscopic colorectal surgery performed with the aid of LigaSure vessel-sealing system or Ultracision . METHODS: Patients eligible for elective laparoscopic right or left hemicolectomy or anterior resection of rectum were randomly assigned to either the use of Ligasure or Ultracision . The primary end point was intraoperative reduction of blood loss. Secondary end points were intraoperative and postoperative morbidity and operative time. RESULTS: Between April 2005 and December 2006, 140 consecutive patients were included in the study (70 Ligasure and 70 Ultracision ). We performed 31 right hemicolectomies, 69 left hemicolectomies, and 40 anterior resections of rectum. Blood loss was 109.6 ml (Ultracision 107.9 ml vs. Ligasure 111.2 ml, P value = 0.72). Intraoperative complication rate was 2.8 percent (Ultracision 1.4 percent vs. Ligasure 4.2 percent, P value < 0.01). Postoperative mortality was 0.7 percent. The overall conversion rate was 7.8 percent, 6 in the Ligasure group and 5 in the Ultracision group (P value = 0.09). Operative time, considered from pneumoperitoneum to minilaparotomy, was 115.7 minutes (Ultracision 114.8 minutes vs. Ligasure 116.3 minutes, P value = 0.89). CONCLUSIONS: Results showed that Ligasure and Ultracision are both useful instruments for laparoscopic colorectal surgery with no significant difference in terms of intraoperative/postoperative morbidity and operative time. Choice of which technique to perform should be according to the surgeon's preference. © The ASCRS 2009.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=66849115094&origin=inward; http://dx.doi.org/10.1007/dcr.0b013e3181a0a70a; http://www.ncbi.nlm.nih.gov/pubmed/19404071; https://journals.lww.com/00003453-200904000-00020; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00003453-200904000-00020; https://dx.doi.org/10.1007/dcr.0b013e3181a0a70a; https://insights.ovid.com/crossref?an=00003453-200904000-00020
Ovid Technologies (Wolters Kluwer Health)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know