On-line glucose monitoring by using microdialysis sampling and amperometric detection based on 'wired' glucose oxidase in carbon paste
Mikrochimica Acta, ISSN: 0026-3672, Vol: 121, Issue: 1-4, Page: 31-40
1995
- 26Citations
- 12Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In-vitro on-line glucose monitoring is described, based on microdialysis sampling and amperometric detection operated in a flow-injection system. Samples were injected into a two-electrode microcell containing an Ag/AgCl quasi-reference electrode and a glucose enzyme electrode as the working electrode, operated at + 0.15 V vs. Ag/AgCl. The enzyme electrode is constructed by mixing the 'wired' glucose oxidase into carbon paste. {Poly[1-vinylimidazole osmium(4,4′-dimethylbipyridine)Cl)]} was used to 'wire' the enzyme. The non-coated electrodes, cross-linked with poly(ethylene glycol) diglycidyl ether, responded linearly to glucose concentrations up to 60 mM, and were characterized by a sensitivity of 0.23 μA mM cm, when operated in flow injection mode and of 5.4 μAm M cm in steady-state conditions. This sensitivity of the resulting enzyme electrode was 50% lower than that of similarly prepared but non-cross-linked electrodes. However, the cross-linked electrodes showed superior operational and storage stabilities, which were further improved by coating the electrodes with a negatively charged Eastman AQ film. An in-house designed microdialysis probe, equipped with a polysulphone cylindrical dialysis membrane, yielded a relative recovery of 50-60% at a perfusion rate of 2.5 μl/min in a well stirred glucose solution. The on-line set up effectively rejected common interferences such as ascorbic acid and 4-acetaminophen when present at their physiological concentrations. © 1995 Springer-Verlag.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0002485688&origin=inward; http://dx.doi.org/10.1007/bf01248238; http://link.springer.com/10.1007/BF01248238; http://link.springer.com/content/pdf/10.1007/BF01248238; http://link.springer.com/content/pdf/10.1007/BF01248238.pdf; http://link.springer.com/article/10.1007/BF01248238/fulltext.html; https://dx.doi.org/10.1007/bf01248238; https://link.springer.com/article/10.1007/BF01248238; http://www.springerlink.com/index/10.1007/BF01248238; http://www.springerlink.com/index/pdf/10.1007/BF01248238