Thin Wires and Edge Imaging Using Hard Bremsstrahlung Generated by a Microfocal Target of a Betatron
Journal of Nondestructive Evaluation, ISSN: 1573-4862, Vol: 41, Issue: 1
2022
- 1Citations
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations1
- Citation Indexes1
Article Description
The magnified images of thin wires, plastic, steel and lead plates which were obtained using linear microfocus hard bremsstrahlung generated through interaction of an 18 MeV electron beam with a 13 μm thick Ta foil oriented along the internal beam of a B-18 betatron are presented. The images indicate high absorption contrast of the objects due to a small horizontal size of the radiation source the width of which is 115-fold smaller than the diameter of the electron beam. Some results have shown a few peculiarities in the images which were not earlier observed. Several results were compared with the ones obtained earlier using the microfocus bremsstrahlung generated by the 18 MeV electron beam of B-18 in a narrow Si target.
Bibliographic Details
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know