A High Resolution/Accurate Mass (HRAM) Data-Dependent MS Neutral Loss Screening, Classification, and Relative Quantitation Methodology for Carbonyl Compounds in Saliva.

Citation data:

Journal of the American Society for Mass Spectrometry, ISSN: 1879-1123, Vol: 28, Issue: 4, Page: 608-618

Publication Year:
2017
Usage 15
Abstract Views 15
Captures 5
Readers 5
Social Media 3
Tweets 3
PMID:
27785693
DOI:
10.1007/s13361-016-1521-y
Author(s):
Dator, Romel, Carrà, Andrea, Maertens, Laura, Guidolin, Valeria, Villalta, Peter W, Balbo, Silvia
Publisher(s):
Springer Nature
Tags:
Biochemistry, Genetics and Molecular Biology, Chemistry
Most Recent Tweet View All Tweets
article description
Reactive carbonyl compounds (RCCs) are ubiquitous in the environment and are generated endogenously as a result of various physiological and pathological processes. These compounds can react with biological molecules inducing deleterious processes believed to be at the basis of their toxic effects. Several of these compounds are implicated in neurotoxic processes, aging disorders, and cancer. Therefore, a method characterizing exposures to these chemicals will provide insights into how they may influence overall health and contribute to disease pathogenesis. Here, we have developed a high resolution accurate mass (HRAM) screening strategy allowing simultaneous identification and relative quantitation of DNPH-derivatized carbonyls in human biological fluids. The screening strategy involves the diagnostic neutral loss of hydroxyl radical triggering MS fragmentation, which is only observed in positive ionization mode of DNPH-derivatized carbonyls. Unique fragmentation pathways were used to develop a classification scheme for characterizing known and unanticipated/unknown carbonyl compounds present in saliva. Furthermore, a relative quantitation strategy was implemented to assess variations in the levels of carbonyl compounds before and after exposure using deuterated d -DNPH. This relative quantitation method was tested on human samples before and after exposure to specific amounts of alcohol. The nano-electrospray ionization (nano-ESI) in positive mode afforded excellent sensitivity with detection limits on-column in the high-attomole levels. To the best of our knowledge, this is the first report of a method using HRAM neutral loss screening of carbonyl compounds. In addition, the method allows simultaneous characterization and relative quantitation of DNPH-derivatized compounds using nano-ESI in positive mode. Graphical Abstract ᅟ.

This article has 0 Wikipedia reference.