Single-stage EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction
Gastrointestinal Endoscopy, ISSN: 0016-5107, Vol: 89, Issue: 1, Page: 69-76
2019
- 119Citations
- 80Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations119
- Citation Indexes119
- 119
- Captures80
- Readers80
- 80
Article Description
EUS-guided choledochoduodenostomy (EUS-CD) using a lumen-apposing metal stent (LAMS) has recently been reported as an alternative treatment approach for patients with malignant obstructive jaundice and failed ERCP. We analyzed the safety and technical and clinical efficacy of EUS-CD using LAMSs in patients with malignant obstructive jaundice. This was a retrospective study of consecutive patients with inoperable malignant distal bile duct obstruction who underwent EUS-CD using an electrocautery-enhanced (EC)-LAMS over a 3-year period (2015-2018). The main outcome measures were technical and clinical success (defined as a decline in serum bilirubin level by 50% at 2-week follow-up). Secondary outcomes were occurrence of adverse events, procedure time, and stent patency. Forty-six patients (47.8% women; median age, 73.1 ± 12.6 years) underwent direct EUS-CD using the biliary EC-LAMS. The procedure was technically successful in 43 patients (93.5%). The rate of clinical success was 97.7%. Adverse events occurred in 5 (11.6%) patients and included the following: 1 fatal bleeding 17 days after stent placement, 3 episodes of stent occlusion (food impaction), and 1 spontaneous migration (all 4 requiring reintervention). The mean follow-up was 114.37 days (95% confidence interval, 73.2-155.4). EUS-CD using the EC-LAMS is effective. The rate of adverse events including one fatal event is not negligible and should be carefully considered before using the stent in this clinical setting. Prospective studies are required to validate our preliminary findings to fully assess the long-term efficacy and safety of the stent.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0016510718330062; http://dx.doi.org/10.1016/j.gie.2018.08.047; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85055496123&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/30189198; https://linkinghub.elsevier.com/retrieve/pii/S0016510718330062; https://dx.doi.org/10.1016/j.gie.2018.08.047
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know