8-inch-diameter field of view for X-ray differential phase-contrast imaging
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN: 0168-9002, Vol: 1004, Page: 165375
2021
- 4Citations
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The X-ray differential phase-contrast imaging (DPCI) based on Talbot–Lau interferometers (TLIs) is a promising imaging technique for non-destructive testing. The compact imaging configurations that have a large field-of-view (FoV) require the use of bent phase gratings and large-area analyzer gratings. The cascaded TLIs reduce the aspect ratio requirement of large-area analyzer gratings, which facilitates the fabrication of these gratings. However, the bent silicon-based phase gratings are difficult to obtain directly because of the brittleness of silicon wafers. In this work, we present a method to prepare 5-inch cylindrically bent silicon-based phase gratings and 8-inch analyzer gratings. Moreover, we also present their applications in the cascaded TLIs. The mechanical stress that originates from thermal oxidation enables us to cylindrically bend silicon-based phase gratings. Furthermore, as compared to the use of plane phase gratings, the use of cylindrically bent phase gratings allows Moiré fringes to appear in the entire 8-inch FoV. Finally, Moiré fringes and multi-contrast images of the samples (water, liquid soap filled in heat-shrink tubes) demonstrate the effectiveness of the fabrication of the bent silicon-based phase gratings and imaging in the entire 8-inch FoV. The proposed configuration is applicable for attaining multi-contrast images with 8-inch FoV at a low cost.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0168900221003594; http://dx.doi.org/10.1016/j.nima.2021.165375; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85105338407&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0168900221003594; https://dx.doi.org/10.1016/j.nima.2021.165375