Effect of Corneal Thickness on Dynamic Contour, Rebound, and Goldmann Tonometry
Ophthalmology, ISSN: 0161-6420, Vol: 113, Issue: 12, Page: 2156-2162
2006
- 143Citations
- 62Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations143
- Citation Indexes141
- 141
- CrossRef111
- Policy Citations2
- 2
- Captures62
- Readers62
- 62
Article Description
To identify correlations among intraocular pressure (IOP) measurements obtained using the rebound tonometer (RBT), the dynamic contour tonometer (DCT), and the Goldmann applanation tonometer (GAT). The effects of corneal thickness on the measures obtained using each of the 3 tonometers also were examined. Cross-sectional study. One hundred forty-six eyes of 90 patients with ocular hypertension or glaucoma. Intraocular pressure measurements were obtained in all patients using RBT, DCT, and GAT. Central corneal thickness was determined by ultrasound pachymetry. Patients were divided randomly into 6 groups to vary the order in which the tonometers were used. All IOP measurements were made by the same examiner, who was masked to the readings obtained. Intraocular pressure and central corneal thickness. There was good correlation between IOP readings obtained using the RBT and GAT ( r = 0.864; P <0.0001), between DCT and GAT ( r = 0.871; P <0.0001), and between RBT and DCT ( r = 0.804; P <0.0001). Rebound tonometer and DCT readings consistently were higher than GAT measurements (RBT-GAT median difference, 1.4±2.7 mmHg; DCT-GAT median difference, 4.4±2.6 mmHg). A Bland–Altman plot indicated that the 95% limits of agreement between RBT and GAT were −4.3 to 6.4 mmHg (slope = 0.056; P = 0.218), those between DCT and GAT were −0.7 to 9.5 mmHg (slope = 0.016; P = 0.717), and those between RBT and DCT were −3.1 to 9.8 mmHg (slope = −0.041; P = 0.457). Using RBT, the point that best discriminated between patients with an IOP 21 mmHg or less and more than 21 mmHg as determined by GAT was >23.3 mmHg (sensitivity, 66.7%; specificity, 92.1%); using DCT, this point was >22.7 mmHg (sensitivity, 95.6%; specificity, 71.3%). In terms of pachymetry, GAT and RBT behaved similarly. Using these instruments, differences of approximately 3 mmHg were detected between the groups of patients with the thinnest (<531 μm) and thickest (>565 μm) corneas, whereas a significantly lower difference (0.5 mmHg) was noted for the DCT. Measurements obtained both with the RBT and DCT show excellent correlation with those provided by applanation tonometry. Both tonometers tend to overestimate the IOP measured with the GAT, particularly the DCT. This last tonometer seems to be less affected by the corneal thickness.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0161642006008505; http://dx.doi.org/10.1016/j.ophtha.2006.06.016; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33751505840&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/16996599; https://linkinghub.elsevier.com/retrieve/pii/S0161642006008505; https://dx.doi.org/10.1016/j.ophtha.2006.06.016