Internal standard for tip-enhanced Raman spectroscopy
Applied Physics Letters, ISSN: 0003-6951, Vol: 103, Issue: 4
2013
- 11Citations
- 36Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
This article presents a concept for the realization of an internal standard for tip-enhanced Raman spectroscopy and shows a proof-of-principle of this idea. The local enhancement is monitored by the Raman signal of a reference compound chemisorbed on the tip. In this way, we are able to bring a constant amount of the reference material to all measuring points without contamination of the system of interest, and always keep it positioned in the same enhanced field that acts on the analyte on the sample surface. © 2013 AIP Publishing LLC.