Evaluation the biocompatibility and hardness of 3D printed resin material with different times and many rinsing solutions
AIP Conference Proceedings, ISSN: 1551-7616, Vol: 3097, Issue: 1
2024
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
A total 70 samples Disks shape were designed to testes. Gingival fibroblasts of human (Manassas, VA, USA) and MTT assay were applied to measurement of toxic substances or biocompatibility test after washing in (10 and 30min) with (Isopropyl alcohol and Ethyl alcohol). Non washing as a control group in (distilled water). The purpose of the study evaluation the effect of two different types of the alcohols on surface deformation, hardness, and cell viability, of 3D-printed dental resin materials that use to denture base. The mean and standard deviation of shore D hardness were recorded for 10min (CTR, IPA, ETOH) (82.59±2.04,79.21±2.39,76.16±2.37), for 30min (82.59±2.04,76.16±2.57,75.99±2.28). The cell viability highest mean recorded in30min (81.24%,79.05%) with (IPA, ETOH). and (CTR)lowest mean (20.67%). In this study appear significant effect the washing solutions and time on biocompatibility as well as no significant effect on surface texture and hardness of 3d resin materials.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know