Ahmed valve, suture-less implantation: A new approach to an easier technique
Journal of Glaucoma, ISSN: 1536-481X, Vol: 22, Issue: 9, Page: 750-756
2013
- 10Citations
- 33Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations10
- Citation Indexes10
- 10
- CrossRef7
- Captures33
- Readers33
- 30
Article Description
PURPOSE:: Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma. PATIENTS AND METHODS:: Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-up (mean follow-up, 13.23 mo, 6 to 28 mo). RESULTS:: IOP control, defined as IOP≤21 mm Hg with or without antiglaucoma eye drops, was achieved in 82.2% of patients, and 58.8% were able to eliminate antiglaucoma eye drops. Mean surgical time was 9.76±2.60 and 6±0.81 minutes in patients with previous vitrectomy (4 cases). Postoperative complications included transiently increased IOP, transient hyphema, early postoperative hypotony (4 cases), and tube block by the vitreous (2 cases): 1 resolved by Nd:YAG and the other by second vitrectomy. No cases of tube or plate extrusion, plate migration, choroidal or retinal detachment, or vitreous hemorrhage were observed. CONCLUSIONS:: These results are promising and demonstrate a safe and effective alternative to the traditional scleral suture. Our data suggest that Ahmed valve implantation through pars plana with cyanoacrylate is a safe and effective method for refractory glaucoma. Further studies are needed to confirm our observation. Copyright © 2012 by Lippincott Williams & Wilkins.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84890514186&origin=inward; http://dx.doi.org/10.1097/ijg.0b013e318264ba4d; http://www.ncbi.nlm.nih.gov/pubmed/24304908; http://journals.lww.com/00061198-201312000-00014; http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:landingpage&an=00061198-201312000-00014; https://dx.doi.org/10.1097/ijg.0b013e318264ba4d; https://insights.ovid.com/crossref?an=00061198-201312000-00014