Head phantoms for a microwave imaging system dedicated to cerebrovascular disease monitoring
2018 IEEE Conference on Antenna Measurements and Applications, CAMA 2018, Page: 1-3
2018
- 7Citations
- 6Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
This paper presents advances in the realization of a head phantom dedicated to the test of a microwave imaging system in order to assess its performances in a realistic laboratory controlled configuration before a possible clinical application to brain stroke monitoring. The phantom is based upon a rigid 3D-printed structure that delineates several cavities which can be filled up with different biological tissue mimicking liquid mixtures. The phantom structure and the composition of the tissue mimicking mixtures are detailed and, then, some effects of the differences in dielectric properties between the phantom and a real head on the electric field distribution within the phantom are analyzed through numerical simulations.