Clinical, Technical, and Radiologic Outcomes of 182 Implant-Supported Zirconia Single Crowns Using Titanium-Base Abutments: A Retrospective Study
International Journal of Prosthodontics, ISSN: 1942-4426, Vol: 35, Issue: 4, Page: 553-559
2022
- 14Citations
- 32Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations14
- Citation Indexes14
- 14
- Captures32
- Readers32
- 32
Article Description
Purpose: To evaluate the biologic, technical, and radiographic outcomes of CAD/CAM–milled bilayer and monolithic zirconia crowns using implants and Ti-base abutments with up to 5 years of follow-up. Materials and Methods: A total of 182 implant-supported “screw-mentable” (hybrid screw/cement retention) single crowns were evaluated in 118 patients. Ti-base abutments were selected according to the chimney (3.5 or 5 mm) and gingival (1, 2, or 3 mm) heights in the virtual model. Zirconia crowns were designed using CAD/ CAM software and then milled from partially stabilized zirconia blocks. After all crowns were cemented onto Ti-base abutments, they were clinically screwed onto the implants. Both implants and crowns were followed up for up to 5 years, and their clinical, technical, and radiologic results were recorded. Results: A total of 118 patients (86 women and 32 men) who received 182 implant-supported screw-mentable crowns were included in this study. The mean follow-up period was 32 ± 18 months (range: 24 to 60 months) for all implants and crowns. No implant was lost during the follow-up period, yielding a cumulative implant survival rate of 100%. Two technical complications were observed in two bruxer patients, yielding a cumulative restoration survival rate of 98.9%. The marginal bone loss was 0.7 ± 0.5 mm from the baseline radiograph to the radiograph taken at the final recall visit. No implants were diagnosed with peri-implantitis. Conclusion: The outcomes of this study suggest that Ti-base abutments are a feasible and affordable alternative to CAD/CAM abutments and that they can successfully support single zirconia crowns
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85138445136&origin=inward; http://dx.doi.org/10.11607/ijp.7796; http://www.ncbi.nlm.nih.gov/pubmed/35323829; http://quintpub.com/journals/ijp/abstract.php?iss2_id=1828&article_id=22603; https://dx.doi.org/10.11607/ijp.7796; https://www.quintessence-publishing.com/usa/en?iss2_id=1828&article_id=22603