Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: An experimental study
BMC Anesthesiology, ISSN: 1471-2253, Vol: 20, Issue: 1, Page: 244
2020
- 3Citations
- 20Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- Captures20
- Readers20
- 20
Article Description
Background: Low concentrations of morphine are required for safe dosing for intrathecal injections. Sometimes, manual dilution of morphine is performed to achieve these low concentrations, but risks dilution errors and bacterial contamination. The primary goal was to compare the concentrations of morphine and bupivacaine between four groups of syringes. The secondary goal was to investigate the difference in contamination rate between these groups. Methods: Twenty-five experienced anesthesia providers were asked to prepare a mixture of bupivacaine 2.0 mg/ml and morphine 60 μg/ml using 3 different methods as clean and precise as possible. The fourth method used was the aspiration of ampoules prepared by the pharmacy. The concentrations of morphine and bupivacaine were measured by High-Pressure Liquid Chromatography (HPLC). The medication was cultured for bacterial contamination. Results: Group 1 (median 60 μg/ml; 95% CI: 59-110 μg/ml) yielded 3 outliers above 180 μg/ml morphine concentration. Group 2 (76 μg/ml; 95% CI: 72-80 μg/ml) and 3 (69 μg/ml; 95% CI: 66-71 μg/ml) were consistently higher than the target concentration of 60 μg. The group "pharmacy"was precise and accurate (59 μg/ml; 95% CI: 59-59 μg/ml). Group 2 and "pharmacy"had one contaminated sample with a spore-forming aerobic gram-positive rod. Conclusion: Manually diluted morphine is at risk for deviating concentrations, which could lead to increased side-effects. Medication produced by the hospital pharmacy was highly accurate. Furthermore, even when precautions are undertaken, contamination of the medication is a serious risk and appeared to be unrelated to the dilution process.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85091806997&origin=inward; http://dx.doi.org/10.1186/s12871-020-01151-2; http://www.ncbi.nlm.nih.gov/pubmed/32977744; https://bmcanesthesiol.biomedcentral.com/articles/10.1186/s12871-020-01151-2; https://dx.doi.org/10.1186/s12871-020-01151-2
Springer Science and Business Media LLC
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know