Durability of Reinforced Concrete Caisson Parapet Beam Exposed to Mediterranean Seawater after 500 Days
ACI Materials Journal, ISSN: 0889-325X, Vol: 121, Issue: 1, Page: 41-54
2024
- 6Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures6
- Readers6
- Mentions1
- News Mentions1
- 1
Most Recent News
Durability of Reinforced Concrete Caisson Parapet Beam Exposed to Mediterranean Seawater after 500 Days
Title: Author(s): Igor Lapiro, Rami Eid, and Konstantin Kovler Publication: Materials Journal Volume: 121 Issue: 1 Appears on pages(s): 41-54 Keywords: corrosion; durability; galvanized
Article Description
The penetration of chloride ions causes degradation of reinforcing bars, which directly affects the service life of the element. In this study, four different alternatives for the construction of a reinforced concrete (RC) caisson parapet beam are investigated: conventional RC, the addition of a corrosion inhibitor to concrete, and the use of glass fiber-reinforced bars (GFRP) and galvanized steel instead of steel bars. The durability of the RC element under marine environment was studied based on measurements performed both in-place and in well-controlled laboratory conditions on specimens prepared in the laboratory, as well as specimens taken from the actual structural element. It was concluded that the exposure of fresh concrete to seawater splash has no effect on mechanical properties. In addition, galvanized rods were found to be a less effective protection strategy compared to the other alternatives studied. GFRP bars, however, provide better protection than the other tested alternatives, although chloride ion penetration in these bars was found to be more accelerated in an alkaline environment compared to a chloride environment. In contrast to the prevailing approach, which considers plain concrete and according to which the electrical resistance of the concrete decreases because of chloride penetration, this study found that electrical resistance in the reinforced element is increased due to an increase in the amount of corrosion products formed between steel and concrete if no cracks occur. Furthermore, it was found that the potential measured using the half-cell method in all the alternatives slowly increased with time, as well as the corrosion risk in the three alternatives with reinforcing steel. The remaining question is whether this change of potential is a direct characteristic of the corrosion risk. Therefore, more research in this direction is needed.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know