PlumX Metrics
Embed PlumX Metrics

Results of radon CR-39 detectors exposed in schools due two different long-term periods

Nukleonika, ISSN: 1508-5791, Vol: 61, Issue: 3, Page: 385-389
2016
  • 7
    Citations
  • 0
    Usage
  • 6
    Captures
  • 0
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Article Description

The paper deals with the recent survey of indoor radon (Rn) results in schools, where paired CR-39 detectors were simultaneously exposed to different long-term periods, i.e., one detector was exposed during the whole year and the other one in the period of the school year duration. To be able to compare the results obtained, for its analysis, the relative bias and U tests were used. It was found that there are no systematic differences between the results, which points that the exposure of the detector during summer vacations did not affect the estimated average annual radon concentration. The paired results were modelled by a linear function, giving an extremely high coefficient of determination R = 0.99.

Bibliographic Details

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know