Treatment of slaughterhouse wastewater with iron electrodes

WIT Transactions on Ecology and the Environment, ISSN: 1743-3541, Vol: 111, Page: 545-551
2008
  • 2
    Citations
  • 0
    Usage
  • 11
    Captures
  • 0
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Article Description

This study is mainly focused on the electrocoagulation treatment of slaughterhouse wastewater for determining effects of the basic operating parameters such as current density, and supporting electrolyte dosage using iron electrodes. The performance of the cylindrical electrochemical reactor was evaluated in batch experiments. While one pole of the power supply was connecting to the reactor as an anode, the other was connected to a stirrer for operation as a cathode. Experiments were carried out by introducing the cattle slaughterhouse wastewater into the reactor and applying a certain amount of current to the circuit. The removal efficiency of the COD increased with increasing current density. The removal efficiencies of 51.3%, 53.8%, 59.9% and 61.2% were obtained for the current densities of 5, 10, 15, 20 mA/cm with the energy consumptions of 15, 48, 91 and 168 kWh/m respectively. However increasing the NaSO dosage, which was added as a supporting electrolyte, from 0.1 to 0.2 M has an adverse effect on COD removal. It can be concluded from this study that treatment of slaughterhouse wastewater can be achieved by applying electrocoagulation.