Potential for the use of the solitaire stent for recanalization of middle cerebral artery occlusion without a susceptibility vessel sign
American Journal of Neuroradiology, ISSN: 0195-6108, Vol: 35, Issue: 1, Page: 149-155
2014
- 9Citations
- 48Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations9
- Citation Indexes9
- CrossRef3
- Captures48
- Readers48
- 48
Article Description
BACKGROUND AND PURPOSE: Absence of the MCA susceptibility vessel sign (negative MCA susceptibility vessel sign) on gradient recalled-echo MR imaging in acute stroke is commonly associated with in situ stenosis and thrombotic occlusion. We evaluated the effectiveness and safety of the Solitaire stent as the first-line device for the recanalization of MCA occlusion with a negative MCA susceptibility vessel sign. MATERIALS AND METHODS: Thirty-eight consecutive patients presenting with acute ischemic stroke due to MCA occlusion were treated by using the Solitaire AB stent alone or combined with thrombolytic drugs. Among these patients, 11 (7 men and 4 women; median age, 70 years; range, 49-89 years) who underwent multimodal stroke MR imaging before the endovascular procedure and had no MCA susceptibility vessel sign on the initial gradient recalled-echo MR imaging were included in this study. The primary end point was the recanalization of the occluded artery evaluated by the arterial occlusive lesion score. Clinical outcome was assessed at discharge and 90 days, as was the degree of residual MCA stenosis or reocclusion. RESULTS: Successful recanalization (arterial occlusive lesion score ≥ II) without balloon angioplasty was obtained in 9 patients (81.8%). Six patients (54.5%) had an mRS score of ≤2 at 90 days. After a median of 147 days, no patient showed reocclusion on follow-up imaging. There were no symptomatic intracerebral hemorrhages. CONCLUSIONS: The Solitaire stent is a feasible tool as the first-line device for multimodal endovascular recanalization therapy in acute ischemic stroke with a negative MCA susceptibility vessel sign. It has a good rate of successful and complete recanalization and is a fast yet safe procedure.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84892765770&origin=inward; http://dx.doi.org/10.3174/ajnr.a3562; http://www.ncbi.nlm.nih.gov/pubmed/23744693; http://www.ajnr.org/cgi/doi/10.3174/ajnr.A3562; https://syndication.highwire.org/content/doi/10.3174/ajnr.A3562; http://www.ajnr.org/lookup/doi/10.3174/ajnr.A3562; https://dx.doi.org/10.3174/ajnr.a3562; https://www.ajnr.org/content/35/1/149
American Society of Neuroradiology (ASNR)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know