Application of electric system cascade analysis for various system configuration
Chemical Engineering Transactions, ISSN: 2283-9216, Vol: 61, Page: 943-948
2017
- 15Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures15
- Readers15
- 15
Article Description
Ongoing primary reliance on conventional fossil fuel resources such as coal and natural gas (NG) for energy generation may be the most economical method but also the most damaging to the environment. Energy management of power plant via sizing is one of the energy and economical saving methods. In this paper, Electric System Cascade Analysis (ESCA), an analytical pinch method is used for optimally size the generation capacity of power plant and storage capacity of energy storage. Energy can be direct current or alternating current, which require rectifier or converter to convert the energy before transporting. Therefore, energy system configuration has various combination depending on the type of currents on each part of the system configuration. The usage of ESCA will be applied on eight types of system configuration. A hypothetical case study is used to demonstrate the application of ESCA. Results show that the least energy lost due to energy conversion is the system configuration with the same type of current input and output.