Construction and test of an X-ray CT setup for material resolved 3D imaging with Medipix based detectors
Journal of Instrumentation, ISSN: 1748-0221, Vol: 7, Issue: 10, Page: C10007-C10007
2012
- 6Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Conference Paper Description
A prototype computerized tomography (CT) setup has been recently built at Nikhef in order to exploit the material resolved capabilities of Medipix based detectors in X-ray imaging. The CT scanner contains a Hamamatsu 90 kVp microfocus X-ray tube and an entirely remotely controllable sample alignment system. The complete setup is fully integrated with the detector operation software. Moreover the 120 frames/s RelaxD readout system [1] allows real time X-ray imaging of fast moving samples. In this work, the description of the setup is given and the first results obtained with Medipix2 [2] and Timepix [3] detectors are presented. They concern detector calibration with fluorescence lines, CT reconstruction of small biological and non-biological samples and material resolved 3D micro-imaging [4]. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84868227318&origin=inward; http://dx.doi.org/10.1088/1748-0221/7/10/c10007; https://iopscience.iop.org/article/10.1088/1748-0221/7/10/C10007; http://stacks.iop.org/1748-0221/7/i=10/a=C10007?key=crossref.95b93589c2a4035905b9bcef1a372071; https://dx.doi.org/10.1088/1748-0221/7/10/c10007; https://validate.perfdrive.com/9730847aceed30627ebd520e46ee70b2/?ssa=a03cad4b-2d57-46fb-96bd-373e6426ef6b&ssb=16744272861&ssc=https%3A%2F%2Fiopscience.iop.org%2Farticle%2F10.1088%2F1748-0221%2F7%2F10%2FC10007&ssi=87574b37-cnvj-4690-88b5-375aba157ad0&ssk=botmanager_support@radware.com&ssm=365658622424887345772913721541746825&ssn=1e1dff349bf004ee3ebfeb5ae5a52495612f0900c3c4-8990-4f21-a27807&sso=393e1f8c-bc564dd29dea30eef7182d5718cebfaa814464b424d5e114&ssp=76314622931726548963172683095704467&ssq=82950785765759979311529239952899344068961&ssr=NTIuMy4yMTcuMjU0&sst=com.plumanalytics&ssu=&ssv=&ssw=&ssx=eyJ1em14IjoiN2Y5MDAwMGMxZDc2YmItMzk2MS00N2VjLTlkZGItNjdmYTVhZTY2ODdlNS0xNzI2NTI5MjM5NDUzMzI4NDE3NjY0LTEwZmZhNzg4ZTI2NGQ4MzY1NzcwODQiLCJyZCI6ImlvcC5vcmciLCJfX3V6bWYiOiI3ZjYwMDBkNzYzNGE3Ni05ZTRkLTRjMmMtYjJhMC1mYzAzNGMyZjE1MjkxNzI2NTI5MjM5NDUzMzI4NDE3NjY0LWFhZTY4ZTE3MDNmNDNiMmU1NzcxNDcifQ==