Development of system for automatic measurement of transient photocurrent and thermally stimulated current
Ingenieria e Investigacion, ISSN: 2248-8723, Vol: 37, Issue: 1, Page: 75-79
2017
- 1Citations
- 601Usage
- 12Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
This paper presents details of the design and implementation of a system for measuring of thermally stimulated current (TSC) and transient photocurrent (I), developed using the Virtual Instrumentation concept. For that we have used National Instrument hardware and the LabView® package as software. The system is controlled by a virtual instrument (VI) which includes facilities to perform measurements of photocurrent keeping the temperature of the sample and the pressure of the chamber of measurement controlled as well as real time display of the Iph vs t and TSC vs T curves. The system was tested by performing transient photocurrent and TSC measurements on CHNHPbI thin films that are generally used as absorbent layer of solar cells. This type of characterization is very useful to get information of the trapping and recombination processes that affect the transport properties of the devices.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85018666436&origin=inward; http://dx.doi.org/10.15446/ing.investig.v37n1.60765; http://www.revistas.unal.edu.co/index.php/ingeinv/article/view/60765; http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0120-56092017000100010&lng=en&tlng=en; http://www.scielo.org.co/scielo.php?script=sci_abstract&pid=S0120-56092017000100010&lng=en&tlng=en; http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0120-56092017000100010; http://www.scielo.org.co/scielo.php?script=sci_abstract&pid=S0120-56092017000100010; https://dx.doi.org/10.15446/ing.investig.v37n1.60765; https://revistas.unal.edu.co/index.php/ingeinv/article/view/60765
Universidad Nacional de Colombia
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know