A new oxygenator change-out system and procedure
Perfusion, ISSN: 0267-6591, Vol: 21, Issue: 5, Page: 297-303
2006
- 14Citations
- 18Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations14
- Citation Indexes14
- CrossRef14
- 14
- Captures18
- Readers18
- 18
Article Description
Official reports relate that, in the US, one patient/month dies as a result of the emergency oxygenator change-out procedure, and the permanent injury of some patients is the result of current oxygenator change-out procedures or oxygenator failures, both in extracorporeal circulation (ECC) and extracorporeal membrane oxygenation (ECMO). The aim of this article is to evaluate a new system and procedure, dedicated to oxygenator change-out, represented by two three-way stopcocks inserted in the ECC line in use. A dedicated back-up oxygenator and circuit can be easily primed and connected to the dedicated connector on the stopcocks, then blood flow is diverted to the new oxygenator without interruption of the ECC. Tests performed showed that oxygenator change-out can be completed by perfusionists in 62.13 ± 11.12 sec. Results obtained show that the new system and procedure allows fast, safe and reproducible oxygenator change-out without interruption of the ECC. © 2006 SAGE Publications.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know