Computer based laboratory electrocardiogram measurements on the outpatients of the De La Salle University-Medical Center, Dasmarinas, Cavite
1998
- 10Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage10
- Abstract Views10
Thesis / Dissertation Description
Computer based laboratory electrocardiogram (ECG) measurements using the PASCO equipment was conducted simultaneously with a KENZ ECG 106 on 9 outpatients of De La Salle University-Medical Center, Dasmarinas, Cavite. The QRS-wave time interval value of both equipment was compared and analyzed using Within-subject designs of the t-test statistical analysis. Results indicate that there were significant differences on the QRS-wave time interval values between the PASCO ECG QRS-wave readings and the Lead 1 KENZ ECG-106 QRS-wave readings. The said results prompted the study to conclude that the PASCO ECG QRS-wave time interval readings are not comparable to the QRS-wave time interval of the Lead of the KENZ ECG. This conclusion was supported by the PASCO ECG readings on the 7 patients that were tested for the study and were rejected by the t-test analysis. The remaining 3 patients were only accepted because there are not enough data to prove otherwise.