Single Photon Interference by Attenuation
2012
- 27Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage27
- Abstract Views27
Interview Description
This project represents the initial phase of developing a Bell’s Inequality Test of Quantum Mechanics laboratory at Central Washington University. We set up and performed an investigation of the interference of light using a double slit apparatus. For the experiment, a 632.8 HeNe laser beam was passed through an optical system consisting of mirrors, neutral density filters, linear polarizers, irises, multiple lenses and a pinhole. The light was spatially filtered, producing a clean profile, and collimated by the placement of the irises, lenses, and pinhole within the path of the light. The beam intensity was varied using the neutral density filters and polarizers to obtain interference patterns consistent with single photon events. A SBIG ST-7 CCD camera was used as detector and the interference fringes measured using pixel specifications of the CCD chip. The camera was evaluated for effectiveness as a single photon detector by attenuating the beam until its irradiance was consistent with single photon events in the camera pixels for one exposure and examining the signal. These attenuation procedures were then employed using single photon counting modules to detect the interference pattern. The single photon counting modules provided a TTL signal corresponding with single photon detection. A statistical analysis of two detector’s counts is consistent with detection of the phenomenon of single photon interference.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know