Development of a Procedure for Analysis of High Density Lipoprotein Subclasses
1982
- 29Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage29
- Downloads26
- Abstract Views3
Thesis / Dissertation Description
Human serum high density lipoprotein subclasses, HDL2 and HDL3 , were isolated by preparative salt density gradient ultracentrifugation and further analyzed by electrophoresis on a 4 to 15% concentration gradient polyacrylamide gel.The separation of the major classes of serum lipoproteins was achieved after a single ultracentrifugation for 272,000 g at 15°c in a swinging bucket rotor. High resolution concentration gradient gel electrophoresis was found to be particularly suitable for the separation of lipoproteins. The isolation of HDL by precipitation methods, heparin-manganese and dextran-magnesium have also been evaluated in this study, and were found not to completely separate HDL from apo B containing lipoproteins.The combined procedure of salt gradient ultracentrifugation for isolation of serum HDL and concentration gradient polyacrylamide gel electrophoresis analysis of HDL2 and HDL3 was further evaluated with a series of normal and lipemic sera. The results suggested that the new procedures can be adopted by the clinical laboratory for the evaluation of serum HDL subclasses in patients with various cardiovascular diseases.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know