Changing spring stiffness in a shock-absorbing pylon on prosthetic mechanical work during walking
2020
- 34Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage34
- Abstract Views34
Poster Description
A prosthetic shock-absorbing pylon (SAP) is intended to attenuate impact forces, provide comfort, and reduce pain for prosthesis users. However, the effect of SAP spring stiffness on mechanical work done by the prosthetic limb during walking remains unclear. The purpose of this study: to investigate the effects of spring stiffness and walking speed on the mechanical work of the prosthetic limb during stance in individuals with unilateral transtibial amputation (TTA). We hypothesized that: (1) a more compliant spring results in larger negative work during early stance, and subsequently produce larger positive work (i.e., greater energy stored and returned) and (2) increased walking speed will amplify the effects of SAP spring stiffness on mechanical work due to an increase in ground reaction forces. A secondary analysis was performed on 12 unilateral TTA participants, who walked overground on four spring stiffnesses at self-selected customary (1.22±0.01m/s) and fast (1.53±0.01m/s) walking speeds. Joint power and work were calculated using the unified deformable power analysis. Total limb power was estimated as the sum of the prosthesis, knee, and hip power. The stance phase was divided into four phases defined by the fluctuations of negative and positive work done by the total limb: (1) collision (0-20% of stance), (2) rebound (20-54%), (3) preload (54-82%), and (4) push-off (82-100%). Greater magnitude of negative work to positive work from the prosthesis suggests a damping effect. Future research will investigate the source of this net energy loss from the prosthesis its influence on the contralateral limb.