Submerged Parshall Flumes of Small Size
1965
- 1,133Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage1,133
- Downloads1,013
- 1,013
- Abstract Views120
Report Description
The calibration of small Parshall flumes for measuring flows ranging in magnitude from 0.1 to 1.1 cubic feet per second (cfs) was accomplished by A. R. Robinson (1960) at Colorado State University. The purpose of Robinson’s investigation was to accurately calibrate and standardize the design of small Parshall measuring flumes. The rated flumes were constructed of galvanized sheet metal. Data was collected for Parshall flumes having throat widths of 1-, 2-, and 3- inches. Calibration tables or curves were prepared for both free and submerged flow. The dimensions of the Parshall flumes rated by Robinson are shown in Figure 1. The study reported herein was made to illustrate that the analysis of submergence developed at Utah State University (Hyatt, 1965) for trapezoidal flumes is applicable to small Parshall flumes. The data reported by Robinson (1960) is analyzed by the submergence parameters reported by Hyatt (1965) and the resulting equations and calibration curves are listed in this report.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know