Correlation between central corneal thickness measurements using two uifferent ultrasonic pachymeters
Pakistan Journal of Ophthalmology, Vol: 29, Issue: 4, Page: 214-216
2013
- 93Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage93
- Downloads80
- Abstract Views13
Article Description
Purpose: To assess correlation between central corneal thickness measurements using two different ultrasonic pachymeters. Material and Methods: This prospective study involved normal subjects aged 16 to 45 years. Central corneal thickness was measured in 47 eyes by two ultrasonic pachymeters – Tomey SP – 100 and Sonomed 300 AP. Correlations between CCT measurements assessed by the two pachymeters were tested by Pearson correlation. Results: Forty seven eyes were included in the study. The mean (± SD) age of the subjects was 27.79 years (± 6.88).The mean (± SD) Tomey Pachymeter CCT was 536.45 m (34.37) and the mean (SD) Sonomed CCT was 540.64 m (33.48).CCT measurements by the two modalities were very strongly correlated (r = 0.98; P <0.0001). Conclusions: In healthy individuals, Tomey pachymeter measurements of corneal thickness were highly correlated with those obtained using Sonomed pachymeter, and hence the two may be used interchangeably.