Preserved enzymatic activity of glucose oxidase immobilized on unmodified electrodes for glucose detection
Biosensors and Bioelectronics, ISSN: 0956-5663, Vol: 22, Issue: 9, Page: 2158-2164
2007
- 29Citations
- 327Usage
- 26Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations29
- Citation Indexes29
- 29
- CrossRef18
- Usage327
- Downloads322
- Abstract Views5
- Captures26
- Readers26
- 26
Article Description
Glucose sensing electrodes have been realized by immobilizing glucose oxidase (GOx) on unmodified edge plane of highly oriented pyrolytic graphite (epHOPG) and the native oxide of heavily doped silicon (SiO 2 /Si). Both kinds of electrode show direct interfacial electron transfer due to the redox process of the immobilized GOx. The measured formal potential of the redox process agrees with that of the native enzyme, suggesting that the immobilized GOx has retained its enzymatic activity. The electron transfer rates of the GOx immobilized electrode are 2 s −1 for GOx/epHOPG electrode and 7.9 s −1 for GOx/SiO 2 /Si electrode, which are greater than those for which GOx is immobilized on modified electrodes, probably due to the fact that the enzyme makes direct contact to electrode surface. The preservation of the enzymatic activity of the immobilized GOx has been confirmed by observing the response of the GOx/epHOPG and GOx/SiO 2 /Si electrodes to glucose with a detection limit of 0.050 mM. The response signals the catalyzed oxidation of glucose and, therefore, confirms that the immobilized GOx retained its enzymatic activity. The properties of the electrode as a glucose sensor are presented.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0956566306004945; http://dx.doi.org/10.1016/j.bios.2006.10.015; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33847357676&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/17113278; https://linkinghub.elsevier.com/retrieve/pii/S0956566306004945; https://engagedscholarship.csuohio.edu/enece_facpub/56; https://engagedscholarship.csuohio.edu/cgi/viewcontent.cgi?article=1106&context=enece_facpub; https://dx.doi.org/10.1016/j.bios.2006.10.015
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know