Investigation Of Force Decay In Esthetic Composite Orthodontic Archwires
2013
- 933Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage933
- Downloads801
- Abstract Views132
Thesis / Dissertation Description
INVESTIGATION OF FORCE DECAY IN ESTHETIC COMPOSITE ORTHODONTIC ARCHWIRESJacob Spendlove, D.D.S.Marquette University, 2013Introduction:Fiber-reinforced composite archwires have been developed to increase the esthetics of orthodontic appliances. Because polymer containing composites typically exhibit time-dependent stress-strain behavior, deflected fiber-reinforced composite archwires may experience a decrease in force over time. The goal of this research was to determine if esthetic fiber-reinforced composite archwires can maintain continuous light forces without undergoing extreme amounts of force decay.Materials and Methods:Force decay was evaluated by comparing results of 3-point bending tests of nickel-titanium (NiTi) and fiber-reinforced composite archwires. Due to the impracticality of measuring force decay of a single archwire for 30 days, the following protocol was used: each segment was tested in 3-point bending using a universal testing machine to a maximum deflection of 3.1 mm; next, each segment was placed in a custom-made jig designed to deflect each segment either 1 or 2 mm for 30 days. Each segment was once again tested in 3-point bending to examine consistency of the bending profile. Paired t-tests were used to statistically compare pre- and post-deflection forces. A control group consisting of wires not subject to the 30 day constant deflection was tested to ensure that the initial testing did not alter the second 3-point bend test.Results:Statistically significant (pConclusions:The BioMers 1 mm deflection group demonstrated that fiber-reinforced composite archwires are able to deliver a consistent force after 30 days of deflection. However, the clinical applicability of these fiber-reinforced composite archwires may be limited as they are unable to sustain deflections of 2 mm without experiencing crazing and loss of force delivery.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know