Characterization of an Acousto-optic Tunable Filter and Use in Visible Spectrophotometry
1999
- 37Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage37
- Downloads35
- Abstract Views2
Article Description
The use of a paratellurite acousto-optic tunable ® lter (AOTF) is demonstrated as a monochromator for spectrophotometry. This device operates in the range of 400 to 700 nm with a resolution from 2.5 nm (at 633 nm) to 0.5 nm (at 400 nm). Results of the initial characterizations indicate that behavior follows the theoretical model in terms of frequency/wavelength relationships, dependence of the output wavelength upon the incident radiation angle, and bandpass as a function of wavelength. Initial results of spectroscopic characterizations of permanganate, cobalt(II), holmium(III), praseodymium( III), and neodymium(III) solutions are presented. Placing a polarizer in the light path reduced the amount of stray light reaching the detector. Two types of photomultiplier tubes were used as detectors. The sensitivity of the PMTs varied at different wavelengths, which affected spectral responses and the effects of scattered light.