Visual enhancement of MR angiography images to facilitate planning of arteriovenous malformation interventions
ACM Transactions on Applied Perception, ISSN: 1544-3965, Vol: 12, Issue: 1, Page: 1-15
2015
- 6Citations
- 3Usage
- 27Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations6
- Citation Indexes6
- CrossRef5
- Usage3
- Abstract Views3
- Captures27
- Readers27
- 27
Article Description
The primary purpose of medical image visualization is to improve patient outcomes by facilitating the inspection, analysis, and interpretation of patient data. This is only possible if the users' perceptual and cognitive limitations are taken into account during every step of design, implementation, and evaluation of interactive displays. Visualization of medical images, if executed effectively and efficiently, can empower physicians to explore patient data rapidly and accurately with minimal cognitive effort. This article describes a specific case study in biomedical visualization system design and evaluation, which is the visualization of MR angiography images for planning arteriovenous malformation (AVM) interventions. The success of an AVM intervention greatly depends on the surgeon gaining a full understanding of the anatomy of the malformation and its surrounding structures. Accordingly, the purpose of this study was to investigate the usability of visualization modalities involving contour enhancement and stereopsis in the identification and localization of vascular structures using objective user studies. Our preliminary results indicate that contour enhancement, particularly when combined with stereopsis, results in improved performance enhancement of the perception of connectivity and relative depth between different structures.
Bibliographic Details
Association for Computing Machinery (ACM)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know