Lumped Element RF Low Pass Filter with 20 dB Improved Suppression at the Center Frequency of an RF Injection Network for Conductive Emission Testing
2019 IEEE Canadian Conference of Electrical and Computer Engineering, CCECE 2019, Page: 1-2
2019
- 1Usage
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage1
- Abstract Views1
- Captures2
- Readers2
Conference Paper Description
In this work, a modified low pass filter with 20 dB improved rejection at the center frequency of the RF injection network was developed to monitor the RF rectification of an active implantable medical devices (AIMD) during conductive emission testing. Transfer function of the designed filter was calculated, verified and validated by ADS simulation and S-parameter measurement using RF network analyzer. Analytical calculation, simulation and measurement results of the filter transfer function are in good agreement.
Bibliographic Details
Institute of Electrical and Electronics Engineers (IEEE)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know