STR-827: SHEAR STRENGTH OF CIRCULAR CONCRETE BEAMS REINFORCED WITH GFRP BARS
2016
- 532Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage532
- Downloads509
- Abstract Views23
Artifact Description
This paper presents the results of an investigation of the shear strength and behavior of three circular concrete beams reinforced with glass-FRP (GFRP) bars and spirals. The beams, which measured 3,000 mm in length by 500 mm in diameter, were tested under four-point bending. The test parameters included the GFRP-spiral-reinforcement ratio (different spiral spacings [150 and 200 mm] and spiral diameters [13 and 15 mm]). As designed, the beams failed in shear due to GFRP-spiral rupture. The test results indicated that the higher the GFRP spiral reinforcement ratio, the higher the enhancement of the shear strength due to the confinement, which controls shear cracks and improves aggregate interlocking.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know