Kinematics in Total Knee Arthroplasty
2021
- 119Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage119
- Abstract Views81
- Downloads38
Article Description
Total knee arthroplasty (TKA) continues to be a successful procedure for the past 50 years. We investigated the kinematics after under- and overstuffing the joint space with the polyethylene (PE) insert in both cruciate-retaining (CR) TKA and posterior-stabilized (PS) TKA. We compared CR and PS designs to evaluate their respective kinematic differences. This study employed a hybrid computational-experimental joint motion simulation on a 6 degrees of freedom joint motion simulator. Physical prototypes of a virtually performed TKA based on cadaveric CT scans and a virtual ligament model were utilized. We demonstrated understuffing decreases stability and the joint compressive forces, with the inverse occurring with overstuffing. In isolation, understuffing did not result in instability during activities of daily living in CR-TKA. Notably, a 2 mm increase or decrease in PE thickness altered the post-cam mechanism engagement. The PS design demonstrated greater stability, but overall, the kinematics between CR and PS designs were similar. This study demonstrates the ability of a hybrid model to further the understanding of kinematics in TKA.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know