A Novel Hybrid Imaging System to Aid in Surgical Decision Making
2017
- 121Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage121
- Abstract Views74
- Downloads47
Artifact Description
Background:Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.Methods:Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in surgical decision making.Results:A new imaging system has been developed and tested with imaging phantoms.Discussion & Conclusion:Results obtained with imaging phantoms are promising; high resolution images with good contrast have been shown. Further research using surgical excised tumour specimens will be conducted as a pilot study.Interdisciplinary Reflection:Various imaging methods are combined and applied to medical needs. In addition, this imaging system is incredibly versatile and can be used for many areas of research including animal studies, human studies, and from macroscopic imaging to microscopy.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know