Optimizing the Effectiveness of Peripheral Intravenous Catheters
2020
- 451Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage451
- Downloads358
- Abstract Views93
Thesis / Dissertation Description
Problem Hospitalized adult patients require more than one short peripheral catheter (SPC) to complete the prescribed intravenous (IV) therapy due to catheter failure and the practice of resiting. The purpose of this quality improvement initiative was to increase the rate of SPCs remaining in situ for the entire duration of the IV therapy for hospitalized adult patients.Methods Application of an engineered securement device (ESD), an educational program pertaining to modifiable risk factors, and changing the practice to removal upon clinical indication were methods utilized to reduce the number of SPC insertions and catheter failures. This study was conducted at a rural, Midwestern hospital using a convenience sample (N=405) and an observational, descriptive, cohort design in six phases between September 2019 and March 2020.Results Following the practice changes, there was a reduction of SPC replacement (24%), catheter failures (24% to 13%), SPCs per patient (M=2.9 to 2.2 p=.045), SPC insertions (4,000 per year), and zero SPC-related CRBSIs (0.26 per 1000 catheter days to 0.0) and a significant increase of SPCs remaining in situ (M=2.6 to 3.8 days; p=p=.007) and upper arm (p=.026) and significantly reduced when inserted in the forearm (p=0.39).Implications for Practice Study findings suggest the use of an ESD, promoting insertion in the forearm, avoidance of the wrist and upper arm, and the practice change to removal when clinically indicated.