Early hemodynamic assessment using NICOM in patients at risk of developing Sepsis immediately after emergency department triage.
Vol: 29, Issue: 1, Page: 23-23
2021
- 201Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage201
- Downloads156
- Abstract Views45
Article Description
BACKGROUND: One factor leading to the high mortality rate seen in sepsis is the subtle, dynamic nature of the disease, which can lead to delayed detection and under-resuscitation. This study investigated whether serial hemodynamic parameters obtained from a non-invasive cardiac output monitor (NICOM) predicts disease severity in patients at risk for sepsis.METHODS: Prospective clinical trial of the NICOM device in a convenience sample of adult ED patients at risk for sepsis who did not have obvious organ dysfunction at the time of triage. Hemodynamic data were collected immediately following triage and 2 hours after initial measurement and compared in two outcome groupings: (1) admitted vs. dehydrated, febrile, hypovolemicdischarged patients; (2) infectious vs. non-infectious sources. Receiver operator characteristic (ROC) curves were calculated to determine whether the NICOM values predict hospital admission better than a serum lactate.RESULTS: 50 patients were enrolled, 32 (64 %) were admitted to the hospital. Mean age was 49.5 (± 16.5) years and 62 % were female. There were no significant associations between changes in hemodynamic variables and patient disposition from the ED or diagnosis of infection. Lactate was significantly higher in admitted patients and those with infection (p = 0.01, p = 0.01 respectively). The area under the ROC [95 % Confidence Intervals] for lactate was 0.83 [0.64-0.92] compared to 0.59 [0.41-0.73] for cardiac output (CO), 0.68 [0.49-0.80] for cardiac index (CI), and 0.63 [0.36-0.80] for heart rate (HR) for predicting hospital admission.CONCLUSIONS: CO and CI, obtained at two separate time points, do not help with early disease severity differentiation of patients at risk for severe sepsis. Although mean HR was higher in those patients who were admitted, a serum lactate still served as a better predictor of patient admission from the ED.