Detecting Different States of Ventilation with a Wearable Device through Minute Ventilation
2020
- 111Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage111
- Downloads60
- Abstract Views51
Abstract Description
Introduction: Detecting changes in respiration are essential to monitoring a patient’s vital signs. Few devices accomplish this in a non-invasive manner. We are developing a wearable Trachea Sound Sensor that measures respiratory rate (RR), tidal volume (TV), minute ventilation (MV = RR x TV). A prototypical Trachea Sound Sensor (TSS) was created and compared to a reference pneumotachometer. Both were used to record the sounds of breathing with research team members.Methods:The TSS recording device was tested on six research team members and breath sounds were recorded. Simultaneously, the member’s RR and MV was recorded using a calibrated pneumotachometer. The researchers were instructed to adjust their breathing rate and depth while intervals were recorded. Signal processing techniques were used to analyze and produce measurements of RR, TV, and characterize hyperventilatory or hypoventilatory states.Results: Based on the results, we found that it is possible to obtain accurate measures of RR and identify breathing patterns through the TSS. Signal processing and analysis calculated RR, states of hyperventilation and hypoventilation with 98% sensitivity and specificity. Results obtained for measuring TV were less accurate (±100 mL).Discussion: Our results suggest that it is viable to obtain accurate measures of RR and classify breathing sounds solely on measurements of breathing sounds from the TSS. The inaccuracy in TV measurements may be partly due to the systematic error from the pneumotachometer used. The prototypical TSS are suitable for upcoming NIH-funded clinical trials to test the TSS in volunteers and hospitalized patients.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know