Treatment of steroid-induced elevated intraocular pressure with anecortave acetate: a randomized clinical trial.
Vol: 28, Issue: 6, Page: 559-565
2012
- 179Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage179
- Downloads173
- Abstract Views6
Article Description
PURPOSE: The present study is the first randomized clinical trial designed to evaluate the intraocular pressure (IOP)-lowering effect of anecortave acetate (AA) administered at 3 doses (3, 15, or 30 mg) as an anterior juxtascleral depot (AJD) in patients experiencing elevated IOP due to corticosteroid therapy.METHODS: This was a double-masked, randomized, placebo-controlled, multicenter, parallel group trial. Eligible patients had an IOP of at least 24 mmHg and an IOP increase of at least 10 mmHg relative to their IOP before treatment with steroids. A target IOP was established for each patient at baseline. Patients were randomized to 1 of the 4 treatment groups: vehicle, 3 mg AA, 15 mg AA, or 30 mg AA. All patients then received a 0.5 mL AJD of the assigned treatment. Patients returned for scheduled examination visits at weeks 1, 2, 4, 6, months 3, 4, 5, and 6. IOP was measured at each visit as well as best corrected visual acuity (logMAR), ocular motility, eyelid responsiveness, slit lamp examination, and assessment of any adverse events. In addition, at baseline and at exit, a dilated fundus examination was carried out and the lens was examined using LOCS II criteria.RESULTS: Seventy patients were randomized to treatment. At week 4, eyes in the vehicle group showed a 3.4 mmHg (9.1%) decrease from baseline. Reductions for the 3 mg AA (3.1 mmHg, 10.7%) and the 30 mg AA groups (5.4 mmHg, 16.6%) were not significantly different than for vehicle control. However, IOP for the 15 mg AA group at week 4 was reduced 11.5 mmHg (31.3%) from baseline, which was statistically significant (P=0.0487). The mean time to treatment failure was 32.2, 38.9, 56.3, and 32.6 days for the vehicle, 3 mg AA, 15 mg AA, and 30 mg AA groups, respectively. Adverse events were assessed at each post-treatment visit. There were no serious adverse events that were determined to be related to the test article or its administration.CONCLUSIONS: AA can be of benefit to some patients requiring treatment with corticosteroids, but suffering from the side effect of elevated IOP.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know