Investigation on Electrogenerated Active Chlorine from diluted NaCl Solutions at Ti/Pt Anode
Journal of Electrochemistry, Vol: 15, Issue: 2
2009
- 141Usage
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage141
- Downloads133
- Abstract Views8
Article Description
Electrogeneration of active chlorine from diluted NaCl solutions was investigated in an undivided cell with Ti/Pt anode and Ti plate cathode.The effects of electrolysis time,current density(i),chloride concentration and pH value on the electrogeneration of active chlorine and current efficiency(CE) were analyzed.Meanwhile,the changing trends of the electrolyte's conductivity(TSD) and pH value in the electrolysis process were discussed.The results showed that the concentration of active chlorine increased with electrolysis time,but the trend became slow.During this process,the current efficiency reduced steadily.When i was 4.93~7.39 mA/cm2,the concentration of active chlorine increased with the increase of i,but no longer increased when the i exceeded 7.39 mA/cm2.The concentration of active chlorine and CE increased with the increase of NaCl concentration,but the increased range reduced.Acidic electrolyte was beneficial to electrogeneration of active chlorine.During the electrolysis,the TSD decreased steadily and the change of pH value did not exceeded 1.
Bibliographic Details
(Xiamen: Dianhuaxue Bianjibu) Editorial Office of Journal of Electrochemistry, Xiamen University
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know