Research of neutral line coupling method in low voltage power line carrier communication
Vol: 38, Issue: 4, Page: 222-229
2023
- 16Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage16
- Downloads13
- Abstract Views3
Artifact Description
Aiming at the instability of low‑voltage power line carrier communication(PLC) problem caused by many factors including line attenuation, load characteristics and so on, a neutral line coupling method of low‑voltage PLC is proposed in this paper. Firstly, the topological structure of low‑voltage distribution area is analyzed. Secondly, the principle of neutral line coupling method of low‑voltage PLC is described, and the PLC channel models of neutral line coupling in this paper are established. Then the performance of neutral line coupling of PLC is simulated using Matlab software. Finally, the accuracy and application effect of neutral line coupling is evaluated with practical cases. The results show that the neutral line coupling method in this paper reduces the attenuation of PLC channel by more than 24.9 dB under the typical five branch heavy load line conditions; after on‑site construction, the success rate of data acquisition is significantly improved. It has many advantages such as high safety and easy construction, and can be used as an effective operation and maintenance means for PLC in low‑voltage distribution area.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know