Effect of Supporting Soil on the Seismic Response of Elevated Water Tanks under Different Excitations
Bulletin of the Faculty of Engineering. Mansoura University, Vol: 41, Issue: 2, Page: 6-15
2020
- 31Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage31
- Downloads29
- Abstract Views2
Article Description
Elevated water tanks are generally used to provide a high fluid pressure before distribution through pipe network. This may be the most economic mean to control the water distribution to different locations with the needed pressure. During earthquakes, the elevated water tanks have a very important role because the contained water can be used to resist fires which generally occur after earthquakes. Small numbers of researches have been done on the seismic behavior of this type of structures compared to the importance of the problem. The important factors that influence the seismic behavior of such structures are the dynamic properties of the tank itself, the structure-soil system and the excitation time history. Soil type and different excitations time histories are the governing factors in this study. A three dimensional model is constructed to analyze the problem. Time History analysis has been performed using the method of finite elements. In the analysis, the tank material is assumed to be reinforced concrete. The Mohr-Coulomb model has been used to describe the behavior of the soil model. Kobe, Northridge and El-Centro Earthquake records are used in this study as the bedrock Excitation. The study focuses on the horizontal and vertical displacements of the tank. The results show the effect of different types of supporting soil and different excitations on the seismic response of the tank.
Bibliographic Details
Egypts Presidential Specialized Council for Education and Scientific Research
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know