Depth of cure of resin composites: effect of incremental layering versus bulk placement and effect of curing light type
2018
- 285Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage285
- Abstract Views145
- Downloads140
Thesis / Dissertation Description
Background: The introduction of resin composite was a revolution in dentistry and it has shown a high level of success as a direct restorative material. Appropriate techniques and light curing units are essential for optimal clinical outcomes. Objective: To assess depth of cure of two bulk-fill composites and one nanofill resin composite, when photopolymerized with two different curing light units (CLU), placed with an incremental layering versus bulk-fill technique. Material and methods: Two Bulk-fill resin composites (Surefil SDR® Flow and Tetric EvoCeram®) and a conventional nanofill (FiltekTM Supreme Ultra) were used to prepare 90 cylindrical specimens. Specimens (n=5/group) were made using two placement techniques (incremental and bulk-fill). Each specimen was polymerized using one of two LCUs (Valo® LED [standard power or extra- power mode] and OptiLux 501® QTH), with irradiation times set according to the manufacturer recommendations. Vickers microhardness was evaluated starting from the top to the bottom surface of each specimen. Ten measurements were made sequentially (0.4 mm intervals). A three-way ANOVA and Tukey’s post hoc test was used (significance of 0.05) to analyze the DOC data. Results: All resin composite groups cured with LED CLU (extra-power for 3 sec) and placed using a bulk-fill technique showed significant differences (p<0.05) in hardness ratio (DOC analysis). Conclusions: An incremental insertion technique showed a significantly higher DOC for all composite resin groups when compared to bulk insertion. Therefore, it is not recommended to use a bulk-fill technique with conventional composite. Delivering high irradiance(3200 mW/cm2) and exposure time (3 sec) for LED CLU did not exceed the threshold value for bottom to top hardness ratio of 80% at 4 mm as claimed for Bulk-fill composites when using a bulk-fill insertion technique. Tetric EvoCeram Bulk Fill achieved a 3.2-mm DOC when LED CLU standard power was used for 10 seconds using a bulk-fill insertion technique. The best results were achieved with combinations of incremental insertion and use of a QTH curing light with extended curing time (40 sec).