Laser ablation sample transfer for localized LC-MS/MS proteomic analysis of tissue
Journal of Mass Spectrometry, ISSN: 1096-9888, Vol: 51, Issue: 4, Page: 261-268
2016
- 26Citations
- 133Usage
- 29Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations26
- Citation Indexes26
- 26
- CrossRef25
- Usage133
- Downloads133
- Captures29
- Readers29
- 29
Article Description
We have developed a mid-infrared laser ablation sampling technique for nano-flow liquid chromatography coupled with tandem mass spectrometry proteomic profiling of discrete regions from biological samples. Laser ablation performed in transmission geometry was used to transfer material from 50-μm thick tissue sections mounted on a glass microscope slide to a capturing solvent. Captured samples were processed using filter-aided sample preparation and enzymatically digested to produce tryptic peptides for data-dependent analysis with an ion trap mass spectrometer. Comparison with ultraviolet laser capture microdissection from neighboring regions on the same tissue section revealed that infrared laser ablation transfer has higher reproducibility between samples from different consecutive sections. Both techniques allowed for proteomics investigation of different organelles without the addition of surfactants.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84962110848&origin=inward; http://dx.doi.org/10.1002/jms.3744; http://www.ncbi.nlm.nih.gov/pubmed/27041656; https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jms.3744; https://repository.lsu.edu/chemistry_pubs/971; https://repository.lsu.edu/cgi/viewcontent.cgi?article=1971&context=chemistry_pubs; https://digitalcommons.lsu.edu/chemistry_pubs/971; https://digitalcommons.lsu.edu/cgi/viewcontent.cgi?article=1971&context=chemistry_pubs
Wiley
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know