Currents’ physical components (CPC) of the supply current of unbalanced lti loads at asymmetrical and nonsinusoidal voltage
Przeglad Elektrotechniczny, ISSN: 0033-2097, Vol: 93, Issue: 9, Page: 30-35
2017
- 4Citations
- 6Usage
- 1Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- Usage6
- Abstract Views6
- Captures1
- Readers1
Article Description
Power properties of unbalanced linear time-invariant (LTI) loads in three-phase three-wire circuits at asymmetrical and nonsinusoidal supply voltages are investigated in this paper. It is demonstrated that the supply current of such loads can be decomposed into Currents’ Physical Components (CPC), associated with distinctive physical phenomena in the load. The power equation is developed and it is also demonstrated how the current components can be expressed in terms of the supply voltage and the equivalent parameters of the load.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85028727637&origin=inward; http://dx.doi.org/10.15199/48.2017.09.06; http://sigma-not.pl/publikacja-109140-2017-9.html; https://repository.lsu.edu/eecs_pubs/439; https://repository.lsu.edu/cgi/viewcontent.cgi?article=1438&context=eecs_pubs; https://digitalcommons.lsu.edu/eecs_pubs/439; https://digitalcommons.lsu.edu/cgi/viewcontent.cgi?article=1438&context=eecs_pubs; https://dx.doi.org/10.15199/48.2017.09.06; https://sigma-not.pl/home.xhtml
Wydawnictwo SIGMA-NOT, sp. z.o.o.
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know