Analisis Asam Valproat dalam Plasma Secara Kromatografi Gas
Pharmaceutical Sciences and Research, ISSN: 2407-2354, Vol: 7, Issue: 3
2010
- 1,258Usage
- 31Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage1,258
- Downloads963
- Abstract Views295
- Captures31
- Readers31
- 31
Article Description
Valproic acid is an anticonvulsant drug that works by increasing the levels of γ-aminobutyric acid (GABA). Determination of valproic acid is quite difficult because it has no chromophore groups in its structure. Aa analytical method using gas chromatography (GC) with flame ionization detector for the determination of valproic acid in human plasma has been developed and optimized. Valproic acid was extracted from plasma by liquid-liquid extraction method using diethyl ether. The optimum analysis conditions for valproic acid in plasma were achieved by regulated gas chromatography injector and detector at a temperature of 250oC and temperature programming with an initial temperature of 70oC and 5oC temperature increasing per minute until a temperature of 100oC, then held for 1 minute. Then the temperature was increased by 2°C per minute until the column temperature to 150oC. The optimum conditions of analysis took 32 minutes. In the concentration range from 40.0 to 100.0 µg/mL yielded a linear calibration curve with correlation coefficient (r) of 0.9894. Accuracy (% diff) of this method was -13.67% to 12.33% with precision (CV) between 9.33% to 14.92%, and relative recovery test was 86.33% to 112.33%.
Bibliographic Details
Universitas Indonesia
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know