Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination
Makara Journal of Health Research, ISSN: 2356-3656, Vol: 26, Issue: 1
2022
- 4Citations
- 1,011Usage
- 6Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- CrossRef4
- Usage1,011
- Downloads710
- Abstract Views301
- Captures6
- Readers6
- Mentions1
- News Mentions1
- News1
Most Recent News
Study Findings from Dicle University Advance Knowledge in Health and Medicine (Comparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination)
2023 MAR 03 (NewsRx) -- By a News Reporter-Staff News Editor at Health & Medicine Daily -- Investigators publish new report on agriculture. According to
Article Description
Background: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL).Methods: Thirty extracted single-root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL was also determined using periapical radiography, four EALs, and CBCT. The differences in all measurements were compared with the A-WL. The data were statistically analyzed using one-way analysis of variance (Welch) and Tamhane’s test. The significance level was set at p < 0.05.Results: Compared with other measurement methods, CBCT gave shorter values than the A-WL, and this finding was statistically significant compared with those of the PR and Propex Pixi groups (p = 0.009) (p = 0.024). No significant difference was observed between the other groups (p > 0.05) except the CBCT group (p < 0.05).Conclusions: Root ZX mini and Raypex 6 made measurements close to the A-WL.
Bibliographic Details
Universitas Indonesia
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know