The Role of Biventricular Implantable Defibrillator in Heart Transplant Recipients
J Card Fail, Vol: 25, Issue: 8, Page: 0-0
2019
- 18Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage18
- Abstract Views18
Conference Paper Description
Background: Sudden cardiac death and heart failure are common complications following orthotopic heart transplantation. The role of biventricular implantable cardioverter-defibrillators (BiV ICDs) in this population is unknown with minimal available data. Objective: Highlight the safety and utility of BiV ICD placement among orthotopic heart transplant recipients. Case: A 69-year-old male with a medical history notable for type II diabetes, and prior non-ischemic cardiomyopathy requiring BiV ICD and after that, he needed left ventricular assist device (LVAD) placement and ultimately heart transplantation and explantation of his prior BiV ICD. He developed ischemic cardiomyopathy. Cardiac MRI revealed left ventricular dilation, thinning and dyskinesis in the distribution of the left anterior descending (LAD coronary artery and a reduced ejection fraction of 25%. Cardiac catheterization demonstrated 100% occlusion of the middle left anterior descending coronary artery with distal collateralization. ECG demonstrated RBBB with QRS duration of 157 milliseconds. We proceeded with new BiV ICD on the right side due to vein occlusion on the left side. On 24-month follow up, the patient is doing well with no heart failure admission and no ICD therapy. Conclusions: BiV ICD placement might be a safe and viable option among orthotopic cardiac transplant recipients to manage heart failure and prevent sudden cardiac death.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know