Geotechnical Studies of Foundation of a Tilted Tank at Parikshatgarh, India
1988
- 217Usage
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Usage217
- Downloads209
- Abstract Views8
Conference Paper Description
An overhead tank of 200 KL capacity and 9 m staging was constructed in year 1975 at the ancient historical site at Parikshatgarh, Meerut, India. The depth of foundation is 1.6 m and inner and outer diameters of annular raft is 6.8 m and 10.3 respectively. In year 1978, the overhead tank was observed to be tilted. Detailed geotechnical studies have been conducted in 1987 to find out the causes of tilting of the tank and tilts have been measured every month for last one year. It is interesting to note that in spite of severe tilt of 4.3 cm/meter height the overhead tank has been functioning satisfactorily for last 12 years. A comparison of estimated, permissible and observed total and differential settlements has been made.